UJI KUALITAS MIKROBIOLOGI PADA AIR MINUM ISI ULANG DI KECAMATAN INDIHIANG KOTA TASIKMALAYA DENGAN METODE MEMBRAN FILTER

HIKMAH, SAFFANAH ENDAH NURUL (2025) UJI KUALITAS MIKROBIOLOGI PADA AIR MINUM ISI ULANG DI KECAMATAN INDIHIANG KOTA TASIKMALAYA DENGAN METODE MEMBRAN FILTER. Diploma thesis, UNIVERSITAS BAKTI TUNAS HUSADA TASIKMALAYA.

[img] Text (Cover dan Abstrak)
File 1 Cover, Abstark Indonesia, Abstrak Inggris.pdf

Download (410kB)
[img] Text (BAB I - BAB V)
File 3 Bab I - V.pdf
Restricted to Repository staff only

Download (745kB) | Request a copy
[img] Text (Daftar Pustaka)
File 4 Daftar Pustaka.pdf

Download (195kB)

Abstract

PROGRAM STUDI DIII ANALIS KESEHATAN FAKULTAS ILMU KESEHATAN UNIVERSITAS BAKTI TUNAS HUSADA Karya Tulis Ilmiah, Juli 2025 SAFFANAH ENDAH NURUL HIKMAH ABSTRAK Air minum isi ulang menjadi pilihan masyarakat karena harganya yang terjangkau, namun kualitas mikrobiologinya perlu mendapat perhatian. Penelitian ini bertujuan untuk mengetahui keberadaan bakteri Coliform dan Escherichia coli pada air minum isi ulang, serta menilai kesesuaiannya dengan standar Permenkes No. 2 Tahun 2023. Metoda penelitian yang digunakan adalah deskriptif kuantitatif. Penelitian menggunakan 10 sampel dari depot air minum isi ulang di Kecamatan Indihiang, Kota Tasikmalaya dengan menggunakan metode membran filter. Hasil penelitian menunjukkan bahwa 3 dari 10 sampel (30%) tidak memenuhi standar mikrobiologi, dengan 2 sampel terkontaminasi Coliform (3 dan 2 CFU/100 mL), dan 1 sampel terdeteksi mengandung Coliform (22 CFU/100 mL) serta Escherichia coli (2 CFU/100 mL). Sementara itu, 7 sampel (70%) memenuhi standar. Kata kunci : Depot air minum isi ulang, Coliform , Escherichia coli ABSTRACT Refillable drinking water is the chois of the community because of its affordable price, but the quality of its microbiology needs attention. This study aims to determine the presence of Coliform and Eschericia coli bacteria in refillable drinking water, and asses its conformity wih the standars of the Minister of Helath Regulation No. 2 of 2023. The research method used is quantitative descriptive. The test used 10 samples from refillable drinking water depots in Indihiang District, Tasikmalaya City using the filter membrane method. The results showed that 3 of 10 samples (30%) didnot meet microbiological standards, with 2 samples contaminated with Coliform (3 and 2 CFU/100 mL), and 1 sample detected containing Coliform (22 CFU/100 mL) and Escherichia coli (2 CFU/100 mL ). Meanwhile, 7 Samples (70%) met the standard. Keywords: Refillable drinking water depot, Coliform, Escherichia coli

Item Type: Thesis (Diploma)
Subjects: KTI DIII-Analis Kesehatan/TLM
Divisions: Prodi Analis Kesehatan
Depositing User: A.Md.Ak Saffanah Endah NurulĀ Hikmah
Date Deposited: 11 Sep 2025 08:21
Last Modified: 11 Sep 2025 08:21
URI: https://repository.universitas-bth.ac.id/id/eprint/4692

Actions (login required)

View Item View Item