DARMAWANTI, MEDINA (2022) HITUNG JUMLAH CEMARAN BAKTERI PADA BIOLOGICAL SAFETY CABINET DI LABORATORIUM MIKROBIOLOGI UNIVERSITAS BTH TASIKMALAYA. Diploma thesis, UNIVERSITAS BTH TASIKMALAYA.
Text (COVER DAN ABSTRAK)
COVER DAN ABSTRAK.pdf Download (227kB) |
|
Text (BAB I-V)
BAB I-V.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf Download (408kB) |
Abstract
ABSTRAK Hitung Jumlah Cemaran Bakteri pada Biologycal Safety Cabinet di Laboratorium Mikrobiologi Universitas BTH Tasikmalaya OLEH: MEDINA DARMAWANTI 20119038 Abstrak Laboratorium mikrobiologi merupakan suatu tempat yang digunakan dalam menunjang proses pembelajaran mengenai penyakit infeksi yang disebabkan oleh mikroorganisme, uji kepekaan, serta penelitian yang berhubungan dengan mikroba atau bakteri. BSC (Biologycal Safety Cabinet) merupakan salah satu alat yang digunakan dalam penanganan mikroorganisme di Laboratorium yatu sebagai pencegahan penyebaran kontaminasi di laboratorium khusunya di laboratorium mikrobiologi. Dilakukan penelitian pencemaran mikroba pada BSC dengan perlakuan sebelum dan setelah penyinaran UV, dengan tujuan untuk mengetahui pencemaran mikroba pada alat BSC dengan melakukan pemeriksaan secara bakteriologik berupa Angka Lempeng Total (ALT). Metode penelitian yang digunakan adalah metode dekskriptif. Sampel diperiksa Angka Lempeng Totalnya dengan melakukan pengenceran 10-1, 10-2, dan 10-3 dengan larutan pengencer NaCl 0,9 steril. Kemudian, sampel diperiksa secara duplo dengan menuangkan 100ul masing masing pengenceran pada media PCA dan diinkubasi selama 24 jam pada suhu 37ºC. Dari hasil penelitian Angka Lempeng Total yang diambil pada 5 titik permukaan meja BSC bahwa angka kontaminasi sebelum penyinaran UV sangat tinggi yaitu sebanyak 3,9x104 CFU/mL dan Setelah penyinaran UV mengalami penurunan angka kontaminasi dengan diperoleh hasil yaitu sebanyak 0 CFU/mL. Kata Kunci: Angka Lempeng Total (ALT), Kontaminasi, BSC, sinar Ultra Violet Abstract A microbiology laboratory is a place used to support the learning process regarding infectious diseases caused by microorganisms, sensitivity testing, and research related to microbes or bacteria. BSC (Biological Safety Cabinet) is one of the tools used in handling microorganisms in the laboratory, which is to prevent the spread of contamination in the laboratory, especially in the microbiology laboratory. A study of microbial contamination of BSC was conducted with treatment before and after UV irradiation, to know microbial contamination of the BSC device by conducting a bacteriological examination in the form of Total Plate Number (ALT). The research method used the descriptive method. Samples were examined for total plate count by diluting 10-1, 10-2, and 10 3 with a sterile 0.9 NaCl diluent. Then, the samples were examined in duplicate by pouring 100ul of each dilution on PCA media and incubating for 24 hours at 37ºC. From the results of the study, the Total Plate Numbers taken at 5 points on the BSC table surface showed that the contamination rate before UV irradiation was very high, that is 3,9x104CFU/mL and after UV irradiation, the contamination rate decreased with the result that it was 0 CFU/mL. Keywords: Total Plate number (ALT), Contamination, BSC, Ultra Violet Rays
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | KTI DIII-Analis Kesehatan/TLM |
Divisions: | Prodi Analis Kesehatan |
Depositing User: | A.Md.Ak. Medina Darmawanti |
Date Deposited: | 19 Sep 2022 04:16 |
Last Modified: | 19 Sep 2022 04:16 |
URI: | https://repository.universitas-bth.ac.id/id/eprint/1949 |
Actions (login required)
View Item |